Modbus Register Information (Only for RS485 Modbus Model) |
Parameters Function |
Register Add. (HEX/DEC) |
PLC Add.
(Index Number) |
Note |
Modbus RTU Device Control Register |
RTU Device ID |
0x0200/ 512 |
513 |
Factory Default RTU ID:01, Available Range: 1~254 |
Modbus Baud Rate |
0x0201 / 513 |
514 |
0:1200; 1:2400; 2: 4800; 3:9600 (Default); 4:19200; 5:38400 /bps
Baud Rate, No Parity Check, 8 bits, 1 parity check |
Modbus Type |
0x0202 / 514 |
515 |
0:Modbus RTU protocol (Default); 1:Modbus ASCII |
Parity Check |
0x0203 / 515 |
516 |
0: No Parity Check (Default);
1: Even; 2:Odd |
Data bit |
0x0204/ 516 |
517 |
1: 8 bits (unchangeable) |
Stop bit |
0x0205/ 517 |
518 |
0: 1 stop (default) ; 1: 2 stop /bit |
Response Delay |
0x0206/ 518 |
519 |
0~255: the number should be multiplied by 10 to determine the delay time in m.S.
Default value is 0, no response delay. |
Actively send data |
0x0207/ 519 |
520 |
0~255 second, default: 0, disable |
Soil Sensor Register Table |
Temperature |
0x0000 / 0 |
1 |
Function Code: 3/ 4; INT 16, R/O;
(-4000~8000 ) /100= - 40.00~80.00˚C |
Humidity |
0x0001 / 1 |
2 |
Function Code:3/ 4, UNIT 16, R/O; (0~10000) / 100 = 0~100% Humidity |
Electric Conductive |
0x0002 / 2 |
3 |
Function Code:3/ 4, UNIT 16, R/O; 0~20000 (0~20000us/cm) |
Salinity |
0x0003/ 3 |
4 |
Function Code:3/ 4, UNIT 16, R/O; 0~20000 (0~ 20000mg/L) |
Total Dissolved Solid (TDS) |
0x0004/ 4 |
5 |
Function Code:3/ 4, UINT 16, R/O;
0~20000 (0~20000mg/L) |
Permittivity Constant |
0x0005/ 5 |
6 |
Function Code:3/4, UNIT 16, R/O;
0~8200 (0.00~82.00) F/m |
Soil Type |
0x0020/ 32 |
33 |
Function Code:3/6/16, UNIT 16, R/W;
0:Mineral Soil, 1:Sandy Soil, 2:Clay, 3:Organic Soil (default 0: mineral soil) |
Temperature Symbol |
0x0021/ 33 |
34 |
Function Code:3/6/16, UNIT 16, R/W;
0: Celsius ( ˚C); 1:Fahrenheit (˚F)
Default “0” |
Temperature coefficient of conductivity |
0x0022 / 34 |
35 |
Function Code:3/6/16, UNIT 16, R/W;
0~100 corresponding to 0.0% ~ 10.0%
Default 20 (2%) |
Temperature coefficient of salinity |
0x0023/ 35 |
36 |
Function Code:3/6/16, UNIT 16, R/W;
0~100 corresponding to 0.00% ~ 1.0%
Default 55 (0.55) |
Temperature coefficient of T.D.S. |
0x0024/ 36 |
37 |
Function Code:3/6/16, UNIT 16, R/W;
0~100 corresponding to 0.00% ~ 1.0%
Default 50 (0.5) |